===== Manual for LoTHR Electronics Station ==== | ===== Manual for LoTHR Electronics Station ==== | ||
+ | Aka: Mini-TESLA | ||
+ | |||
+ | {{:realraum:qr_lothr_etech_manualwiki.png?direct&180|}} | ||
+ | ShortURL: http://shorturl.at/efoAE | ||
+ | |||
+ | **Main-Power-Switch for everything**: located at back of box. | ||
==== The Electric Load XY-FZ35 ==== | ==== The Electric Load XY-FZ35 ==== | ||
Line 17: | Line 23: | ||
=== Settings === | === Settings === | ||
+ | |||
+ | {{ :realraum:htb13kozxpduk1rjsszdq6xglpxay.jpg?direct&400|}} | ||
^ Protection Settings °° | ^ Protection Settings °° | ||
Line 24: | Line 32: | ||
| OTP | over-temperature protection (at > 80°C, LCD flickers) | | | OTP | over-temperature protection (at > 80°C, LCD flickers) | | ||
| LVP | undervoltage protection (default 1.5V) \\ When discharging a battery, set this to prevent damage to the battery | | | LVP | undervoltage protection (default 1.5V) \\ When discharging a battery, set this to prevent damage to the battery | | ||
- | |||
- | {{ :realraum:htb13kozxpduk1rjsszdq6xglpxay.jpg?direct&400|}} | ||
- | |||
The electronic load automatically saves the switching state before shutting down and resumes with the last state (power == on/off) | The electronic load automatically saves the switching state before shutting down and resumes with the last state (power == on/off) | ||
- | |||
- | |||
Discharge capacity Statistics: | Discharge capacity Statistics: | ||
Line 96: | Line 99: | ||
- | http://www.quickochina.com/uploads/USERmanual-en.pdf | + | ==== The Power Supply RD-Tech DS30V05A ==== |
- | ==== The Power Supply DS30V05A ==== | + | |
- | ==== The KSGEr solering station ==== | + | * Current-Limit, setable in 0.001A increments |
+ | * Voltage-Lmit, setable in 0.01V increments | ||
+ | * max 5A (but current power supply limits to 72W. Need more? Go to TESLA) | ||
+ | * max 26V (would be max 30V but is Buck-Converter and poewr supply only supplies 29V. Need more? Go to TESLA) | ||
+ | |||
+ | === Usage === | ||
+ | |||
+ | See Manual stuffed into the back. | ||
+ | |||
+ | {{ :realraum:dp30v5a_htb16b51jfxxxxb1xxxxq6xxfxxx7.jpg?direct&700 |}} | ||
+ | {{ :realraum:dp30v5a_htb1maynjfxxxxc9xpxxq6xxfxxxl.jpg?direct&700 |}} | ||
+ | |||
+ | ^ Buttons ^^ | ||
+ | | Set (short press) | Begin or Confirm/End setting current/voltage limit) | | ||
+ | | EncoderKnob Press | Go to next Digit | | ||
+ | | EncoderKnob CW | increase digit | | ||
+ | | EncoderKnob CCW | decrease digit | | ||
+ | | Set (long press) | open additional settings screen \\ program memory locations | | ||
+ | | M1 | recall stored settings from memory location 1 | | ||
+ | | M2 | recall stored settings from memory location 2 | | ||
+ | |||
+ | ==== T12 solering station (KSGER, Quicko) ==== | ||
Software Version: 2.09 | Software Version: 2.09 | ||
Line 106: | Line 129: | ||
[[http://www.quickochina.com/uploads/USERmanual-en.pdf|Link to english Manual]] | [[http://www.quickochina.com/uploads/USERmanual-en.pdf|Link to english Manual]] | ||
- | |||
- | ^Button ^ Use ^ | ||
- | |CW | Lower value / Boostmode | | ||
- | |CCW | Increase Value / Standby | | ||
- | |Press | Select | | ||
- | |Long Press | Menu or exit menu| | ||
- | | CW while pressing | change TIP temperature profile | | ||
- | | CCW while pressing | calibrate Tip (only on newer firmware version) | | ||
If the station detects movement/temperature fluctuations of the tip, it will automatically exit standby mode. | If the station detects movement/temperature fluctuations of the tip, it will automatically exit standby mode. | ||
- | === On / Off === | + | === Usage === |
- | Just turn knob CW. | + | ^ Mode ^ How to get there ^ |
+ | | Hard-Off | Use power-switch right of device | | ||
+ | | On | Enable power-switch on the right and turn knob CW until on | | ||
+ | | Boost-Mode (+ ~60°C for ~5min) | Turn knob CW until device enters boost mode | | ||
+ | | Standby (~120°C) | Turn know CCW until device is in standby mode | | ||
+ | | Sleep (Soft-Off) | Turn knob CCW until sleep mode is selected | | ||
+ | | Set Temperature | Press knob once | | ||
+ | | Menu/Settings | Hold knob down | | ||
+ | | Change Tip Preset | Hold knob down while turning knob CW| | ||
=== Set Temperature === | === Set Temperature === | ||
- | Press knob once and set temperature by turning knob. | + | - Press knob once |
+ | - set temperature by turning knob. | ||
=== Change Soldering Tip === | === Change Soldering Tip === | ||
- | Press knob and turn CW. Then select tip and confirm with button press. | + | - Hold knob down while turning knob CW |
- | + | - Then select tip and confirm with button press. | |
- | === Boos Mode === | + | |
- | + | ||
- | Turn know CW. | + | |
- | + | ||
- | === Standby === | + | |
- | Turn know CCW. | ||
=== Calibration === | === Calibration === | ||
Get Solder-iron-tip temperature meter from TESTLA and go to menu and select calibration. | Get Solder-iron-tip temperature meter from TESTLA and go to menu and select calibration. |