 ===== Manual for LoTHR Electronics Station ==== ===== Manual for LoTHR Electronics Station ====
  
 +Aka: Mini-TESLA
 +
 +{{:​realraum:​qr_lothr_etech_manualwiki.png?​direct&​180|}}
 +ShortURL: http://​shorturl.at/​efoAE
 +
 +**Main-Power-Switch for everything**:​ located at back of box.
  
 ==== The Electric Load XY-FZ35 ==== ==== The Electric Load XY-FZ35 ====
Line 17: Line 23:
  
 === Settings === === Settings ===
 +
 + {{ :​realraum:​htb13kozxpduk1rjsszdq6xglpxay.jpg?​direct&​400|}}
  
 ^ Protection Settings °° ^ Protection Settings °°
Line 24: Line 32:
 | OTP | over-temperature protection (at > 80°C, LCD flickers) | | OTP | over-temperature protection (at > 80°C, LCD flickers) |
 | LVP | undervoltage protection (default 1.5V) \\ When discharging a battery, set this to prevent damage to the battery |  | LVP | undervoltage protection (default 1.5V) \\ When discharging a battery, set this to prevent damage to the battery | 
- 
- {{ :​realraum:​htb13kozxpduk1rjsszdq6xglpxay.jpg?​direct&​400|}} 
- 
  
 The electronic load automatically saves the switching state before shutting down and resumes with the last state (power == on/off) The electronic load automatically saves the switching state before shutting down and resumes with the last state (power == on/off)
- 
-  
  
 Discharge capacity Statistics: ​ Discharge capacity Statistics: ​
Line 96: Line 99:
  
  
-http://​www.quickochina.com/​uploads/​USERmanual-en.pdf +==== The Power Supply ​RD-Tech ​DS30V05A ====
-==== The Power Supply DS30V05A ====+
  
-==== The KSGEr solering station ====+  * Current-Limit,​ setable in 0.001A increments 
 +  * Voltage-Lmit,​ setable in 0.01V increments 
 +  * max 5A (but current power supply limits to 72W. Need more? Go to TESLA) 
 +  * max 26V (would be max 30V but is Buck-Converter and poewr supply only supplies 29V. Need more? Go to TESLA) 
 + 
 +=== Usage === 
 + 
 +See Manual stuffed into the back. 
 + 
 +{{ :​realraum:​dp30v5a_htb16b51jfxxxxb1xxxxq6xxfxxx7.jpg?​direct&​700 |}} 
 +{{ :​realraum:​dp30v5a_htb1maynjfxxxxc9xpxxq6xxfxxxl.jpg?​direct&​700 |}} 
 + 
 +^ Buttons ^^ 
 +| Set (short press) | Begin or Confirm/End setting current/​voltage limit) | 
 +| EncoderKnob Press | Go to next Digit | 
 +| EncoderKnob CW | increase digit | 
 +| EncoderKnob CCW | decrease digit | 
 +| Set (long press) | open additional settings screen \\ program memory locations | 
 +| M1               | recall stored settings from memory location 1 | 
 +| M2               | recall stored settings from memory location 2 | 
 + 
 +==== T12 solering station ​(KSGER, Quicko) ​====
  
 Software Version: 2.09 Software Version: 2.09
Line 106: Line 129:
  
 [[http://​www.quickochina.com/​uploads/​USERmanual-en.pdf|Link to english Manual]] [[http://​www.quickochina.com/​uploads/​USERmanual-en.pdf|Link to english Manual]]
- 
-^Button ^ Use ^ 
-|CW | Lower value / Boostmode | 
-|CCW | Increase Value / Standby | 
-|Press | Select | 
-|Long Press | Menu or exit menu| 
-| CW while pressing | change TIP temperature profile | 
-| CCW while pressing | calibrate Tip (only on newer firmware version) | 
  
 If the station detects movement/​temperature fluctuations of the tip, it will automatically exit standby mode. If the station detects movement/​temperature fluctuations of the tip, it will automatically exit standby mode.
  
-=== On / Off ===+=== Usage ===
  
-Just turn knob CW.+^ Mode ^ How to get there ^ 
 +| Hard-Off | Use power-switch right of device | 
 +| On | Enable power-switch on the right and turn knob CW until on | 
 +| Boost-Mode (+ ~60°C for ~5min) | Turn knob CW until device enters boost mode | 
 +| Standby (~120°C) | Turn know CCW until device is in standby mode | 
 +| Sleep (Soft-Off) | Turn knob CCW until sleep mode is selected | 
 +| Set Temperature | Press knob once | 
 +| Menu/​Settings | Hold knob down | 
 +| Change Tip Preset | Hold knob down while turning knob CW|
  
 === Set Temperature === === Set Temperature ===
  
-Press knob once and set temperature by turning knob.+  - Press knob once 
 +  - set temperature by turning knob.
  
 === Change Soldering Tip === === Change Soldering Tip ===
  
-Press knob and turn CWThen select tip and confirm with button press. +  - Hold knob down while turning ​knob CW 
- +  - Then select tip and confirm with button press.
-=== Boos Mode === +
- +
-Turn know CW. +
- +
-=== Standby ===+
  
-Turn know CCW. 
  
 === Calibration === === Calibration ===
  
 Get Solder-iron-tip temperature meter from TESTLA and go to menu and select calibration. Get Solder-iron-tip temperature meter from TESTLA and go to menu and select calibration.